Jewell DXA-100/200 Series single or dual digital accelerometer Description:

Datasheet DX User's Manual DX Quick Start Guide DXA-100/200 Outline Drawing

The Jewell DXA-100/200 Series single or dual digital accelerometer takes Jewell’s highly accurate analog closed-loop sensor technology to the next level. Tested to meet CENELEC and AREMA standards.

Specifications

Input Range (g)1 ±0.25 ±0.50 ±0.87 ±1.00 ±2.00
Non-linearity (%FRO max2 0.02 0.02 0.03 0.05 0.03
Scale Factor Tolerance (% maximum) 0.05 0.05 0.05 0.05 0.05
Bias (mg) 1.00 1.00 1.00 1.00 1.00
Bias Thermal Sensitivity (mg) 90 90 90 90 90
0° Output Temperature Sensitivity (°/°C, maximum) 0.005 0.005 0.005 0.005 0.005
Bandwidth (-3dB, Hz nominal)3 30 30 30 30 30
Transverse Axis Misalignment (° maximum) 0.5 0.5 0.5 0.5 0.5
Weight 10 oz
Dimensions 3.63 × 2.03 × 2.1 in
Features ? Digital output
? Resolution 8 μg
? Mechanical Shock 1500g 1msec half sine
? Industry Standard EIA-RS485 and EIA-RS422 output
? For use in high shock and vibration environments
? High Precision and Performance
? Low Noise
? Meets CENELEC/AREMA Standards
Applications ? Radar/Antenna Control
? Structural Monitoring
? Linear Acceleration/Deceleration Measuring
? Automatic Train Position Control
? Seismic Monitoring
? Platform Leveling
Interface EIA-RS-485 (default)/EIA-RS-422
Protocol Proprietary (custom)
Output Representation g
Baud Rate4 19200, 38400 (default), 57600, 115200, 230400
Number of Axes 1 or 2
Supply Voltage Range (VDC) 10 to 30
Input Current (mA, maximum) Transmitting: DXA-100-R 32 mA/DXA-200-R 50 mA
Not transmitting: DXA-100-R 22 mA/DXA-200-R 40 mA
Operating Temperature Range -40°C to +85°C
Storage Temperature Range -40°C to +85°C
Protection Class per IEC 529 IP67
NEMA Enclosure Rating 6
Shock Survival 1500g, 1 msec, ? sine
Vibration Survival (grms 20 Hz to 2 KHz) 20
Housing Material Anodized Aluminum
Connector Type MS27476Y10D35P
Recommended Mating Connector MS27473T10B35S